A rare complication: an attempt of retrieval of an aortic valve wrapped with pig tail catheter during transcatheter aortic valve implantation

Nov 14, 2017 by in CARDIOLOGY Comments Off on A rare complication: an attempt of retrieval of an aortic valve wrapped with pig tail catheter during transcatheter aortic valve implantation

Abstract Transcatheter aortic valve implantation is preferred to treat high surgical risk patients with severe aort stenosis. Wrapping of a pig tail catheter with device struts during transcatheter aortic valve…

read more

A comparison of drug eluting stent biocompatibility between third generation NOBORI biolimus A9-eluting stent and second generation XIENCE V everolimus-eluting stent in a porcine coronary artery model

Nov 14, 2017 by in CARDIOLOGY Comments Off on A comparison of drug eluting stent biocompatibility between third generation NOBORI biolimus A9-eluting stent and second generation XIENCE V everolimus-eluting stent in a porcine coronary artery model

Abstract Background and purpose NOBORI biolimus A9-eluting stent (BES) is the third generation drug eluting stent (DES) with only abluminal biodegradable polymer. Recent clinical trials have indicated that the BES…

read more

Transcatheter retrieval of device entrapment: management of a rare complication of percutaneous coronary intervention: Case report and literature review

Nov 14, 2017 by in CARDIOLOGY Comments Off on Transcatheter retrieval of device entrapment: management of a rare complication of percutaneous coronary intervention: Case report and literature review

Abstract With the continued advancement in PCI equipment and techniques, complications arising from intracoronary manipulation are encountered. Such complications are associated with major adverse outcome including death; myocardial infarction (MI)…

read more

The impact of precise robotic lesion length measurement on stent length selection: Ramifications for stent savings

Nov 14, 2017 by in CARDIOLOGY Comments Off on The impact of precise robotic lesion length measurement on stent length selection: Ramifications for stent savings

Abstract Background/purpose Coronary stent deployment outcomes can be negatively impacted by inaccurate lesion measurement and inappropriate stent length selection (SLS). We compared visual estimate of these parameters to those provided…

read more

Registro Absorb Italiano (BVS-RAI): an investigators-owned and -directed, open, prospective registry of consecutive patients treated with the Absorb™ BVS: study design

Nov 14, 2017 by in CARDIOLOGY Comments Off on Registro Absorb Italiano (BVS-RAI): an investigators-owned and -directed, open, prospective registry of consecutive patients treated with the Absorb™ BVS: study design

Abstract Background The Absorb™ BVS is a bioresorbable, everolimus-eluting scaffold approved and marketed for coronary use. Published data on long-term results after treatment are limited to a small number of…

read more
Get Clinical Tree app for offline access