A rare complication: an attempt of retrieval of an aortic valve wrapped with pig tail catheter during transcatheter aortic valve implantation




Abstract


Transcatheter aortic valve implantation is preferred to treat high surgical risk patients with severe aort stenosis. Wrapping of a pig tail catheter with device struts during transcatheter aortic valve implantation is a very rare complication. In this report, we present the images and videos of an attempt of retrieval of an aortic valve wrapped with pig tail catheter during transcatheter aortic valve implantation in a 71-year-old man.


A 71-year-old male patient with a previous coronary artery bypass grafting was admitted to our hospital for transcatheter aortic valve implantation (TAVI), based on severe symptomatic aortic valve stenosis (dyspnea ΝΥΗΑ class III–IV, aortic valve area of 0.7 cm 2 with a mean gradient of 44 mm Hg with an ejection fraction of ~ 30% on trans-thoracic echocardiography), high estimated surgical risk (estimated logEuroScore of 36.23%). Multi slice computed tomography was showed a severely calcified tricuspid aortic valve and ascending aort dilatation(48 mm) ( Fig. 1 ).The 18-French sheath was inserted, and after aortic valve predilatation with a 23 mm balloon a 31 mm self-expanding Medtronic CoreValve prosthesis (Medtronic Inc., Minneapolis, USA) was implanted via femoral access. However, despite burst pacing the valve became unseated, and the valve embolised from the annulus distally and lodged at the ascending aort ( Video 1 ). An attempt was made to retrieve the device percutaneously into delivery sheath. But this was unsuccessful and further complicated the procedure by wrapping of a 5 French pig tail catheter (PTC) with device struts. A 0.0035″ guidewire was placed in PTC to straighten and retrieve it. This attempt was ineffective ( Video 2 ). The Snare (En Snare®, Merit Medical, Utah, USA) was inserted through the 6 F sheath on the left femoral artery, and was used to capture PTC that was advanced into the abdominal aorta ( Video 3 ). The corona of CoreValve prosthesis was retrieved up to the aortic bifurcation using the snare but could not be extricated ( Video 4 ). The olive was ruptured during retrieval of delivery sheath. Traumatic acute aortic dissection, extending to femoral artery was seen. The patient was given to surgery. Wrapping PTC and broken olive of delivery sheath was excluded without bleeding by surgery ( Figure 2 A–B ). But patient died due to ventricular fibrillation after repair of aortic dissection in one hour. In conclusion, PTC should be retrieved before gathering the embolised valve due to wrapping of it with valve struts.


Nov 14, 2017 | Posted by in CARDIOLOGY | Comments Off on A rare complication: an attempt of retrieval of an aortic valve wrapped with pig tail catheter during transcatheter aortic valve implantation

Full access? Get Clinical Tree

Get Clinical Tree app for offline access