Left ejection fraction evaluation by speckle tracking

Jul 14, 2017 by in CARDIOLOGY Comments Off on Left ejection fraction evaluation by speckle tracking

Introduction .– The biplane Simpson remains the gold standard for the evaluation of left ventricular ejection fraction (LVEF). However, it allows only a semi-quantitative assessment of the myocardial function without…

read more

Assessment of left ventricular twist mechanics in tako-tsubo syndrome by two-dimensional speckle tracking echocardiography

Jul 14, 2017 by in CARDIOLOGY Comments Off on Assessment of left ventricular twist mechanics in tako-tsubo syndrome by two-dimensional speckle tracking echocardiography

Purpose .– To assess left ventricular (LV) twist mechanics in patients (pts) with tako-tsubo syndrome (TTS). Methods .– Two-dimensional strain and LV twist by speckle tracking echocardiography (echoPACK 7 version…

read more

Speckle tracking is a feasible and reproducible method for the assessment of right ventricular function in patients operated on for congenital heart diseases

Jul 14, 2017 by in CARDIOLOGY Comments Off on Speckle tracking is a feasible and reproducible method for the assessment of right ventricular function in patients operated on for congenital heart diseases

Aim .– Right ventricular (RV) function is a major determinant of prognosis in patients (pts) with congenital heart diseases (CHD), but its evaluation remains challenging. We evaluate feasibility and reproducibility…

read more

Quantitative assessment of left ventricular function by 2D-speckle tracking during exercise: A feasibility study

Jul 14, 2017 by in CARDIOLOGY Comments Off on Quantitative assessment of left ventricular function by 2D-speckle tracking during exercise: A feasibility study

Objectives .– To study the feasibility of quantifying left ventricular (LV) function by 2D-speckle tracking of myocardial deformation during exercise echocardiography in normal subjects. Background .– Accurate assessment of LV…

read more

A new approach to the evaluation of stroke volume and cardiac output by Doppler. Transthoracic echocardiography in the paediatric cardiac ICU

Jul 14, 2017 by in CARDIOLOGY Comments Off on A new approach to the evaluation of stroke volume and cardiac output by Doppler. Transthoracic echocardiography in the paediatric cardiac ICU

Introduction .– Stroke volume (SV-ETT) is hitherto evaluated by transthoracical Doppler (TTE) as: (circular) cross sectional area(CSAO) × velocity time integral (VTI). Cardiac output (CO) can thereof be derived as:…

read more

Éditorial

Jul 14, 2017 by in CARDIOLOGY Comments Off on Éditorial

Bienvenue au 19 e Congrès international d’échocardiographie organisé par la Filiale d’échocardiographie de la Société française de cardiologie (SFC). Avec plus de 1200 participants en 2009, ce Congrès est un rendez-vous…

read more

Interest of speckle tracking for the assessment of right ventricular function in operated tetralogy of Fallot. Comparison with magnetic resonance imaging

Jul 14, 2017 by in CARDIOLOGY Comments Off on Interest of speckle tracking for the assessment of right ventricular function in operated tetralogy of Fallot. Comparison with magnetic resonance imaging

Background .– Right ventricular (RV) function is a major determinant of prognosis in patients (pts) with operated tetralogy of Fallot (ToF), but its evaluation remains challenging. We compared results from…

read more

New RT3DE quantification of global longitudinal, circumferential, radial and area strains: Reproducibility, correlations to cardiac output, and clinical applications

Jul 14, 2017 by in CARDIOLOGY Comments Off on New RT3DE quantification of global longitudinal, circumferential, radial and area strains: Reproducibility, correlations to cardiac output, and clinical applications

Background .– Two-dimensional (2D) speckle tracking echocardiographic strain analysis has demonstrated good capacities in the quantification of left ventricular (LV) contraction but it is limited by LV geometric modelling and…

read more
Get Clinical Tree app for offline access