Perinatal Changes in Fetal Ventricular Geometry, Myocardial Performance, and Cardiac Function in Normal Term Pregnancies




Background


The fetal heart at term is exposed to an increase in hemodynamic work as a consequence of fetal growth, increased circulating volume, and alteration in loading patterns due to maturational changes in fetoplacental circulation. The extent to which these cardiovascular changes influence human fetal and neonatal cardiac adaptation has not been fully elucidated. The aim of this study was to evaluate perinatal cardiovascular changes in ventricular geometry and myocardial performance in normal term fetuses.


Methods


Prospective study of 108 uncomplicated pregnancies delivering at term. M-mode, two-dimensional or B-mode, pulsed wave Doppler, pulsed wave tissue Doppler, and two-dimensional speckle-tracking imaging were performed a few days before and within 24 hours of birth.


Results


Analysis of paired fetal and neonatal echoes demonstrated significant perinatal changes ( P < .0001 for all) in right ventricular (RV) and left ventricular (LV) geometry (RV/LV end-diastolic dimension ratio, 1.2 vs 0.8; RV sphericity index, 0.53 vs 0.40; LV sphericity index, 0.46 vs 0.49). There were corresponding significant ( P < .001 for all) perinatal changes in global myocardial performance: LV myocardial performance index, 0.60 versus 0.47; RV myocardial performance index, 0.61 versus 0.42; systolic function: LV longitudinal systolic strain rate, −1.4/sec versus −1.0/sec; RV longitudinal systolic strain rate, −1.5/sec versus −1.0/sec; RV S′, 5.3 cm/sec versus 6.5 cm/sec; and diastolic function: LV E′/A′, 0.8 versus 1.1.


Conclusions


The findings support the concept that the perinatal period is associated with major changes in fetal ventricular geometry and cardiac function in response to significant alterations in loading conditions. Improved knowledge of perinatal cardiac changes in normal fetuses could facilitate better understanding of cardiac adaptation in normal and pathological pregnancies.


Highlights





  • Establish the feasibility of assessing fetal and neonatal cardiac function.



  • Perinatal period is associated with major changes in fetal ventricular geometry and cardiac function in response to significant alterations in loading conditions.



  • Improved knowledge of perinatal cardiac changes in normal fetuses could facilitate better understanding of cardiac adaptation in normal and pathological pregnancies.



As the heart grows and develops in utero , it is exposed to an increase in hemodynamic work as a consequence of fetal growth, increased circulating volume, and alteration in loading patterns due to maturational changes in fetal and placental circulation. The developing heart may therefore be subject to considerable changes in ventricular geometry, myocardial performance, and cardiac function, especially at near term. The right ventricle is a dominant chamber in fetal life, supplying the lower body organs with less oxygenated blood through the ductus arteriosus. The left ventricular (LV) output directs more oxygenated blood through the ascending aorta to the upper body, feeding the coronary and cerebral circulation. In this parallel fetal circulation, both ventricles are in communication with the descending aorta and have similar systolic pressures but are still subject to different afterloads. Dramatic changes occur at birth with closure of the prenatal shunts, lowering of the pulmonary vascular resistance, increase in systemic vascular resistance, and the two ventricles now functioning in series. Although previous investigators have explored this phenomenon in animal models, only few early and recent human studies have investigated the extent to which these cardiovascular changes influence the human perinatal cardiac adaptation, and they produced conflicting results.


A comprehensive assessment of the fetal heart at term may help to improve the understanding of perinatal fetal cardiac adaptation in normal and pathological pregnancies. Strain and strain rate analysis by tissue Doppler (TDI) and speckle-tracking imaging (STI) has been found to have a stronger correlation to invasive indices of myocardial performance, a higher sensitivity for detecting even mild myocardial damage, and a stronger predictive value for cardiovascular complications than conventional echo indices. In spite of these newer techniques for cardiac imaging, there are few studies using these methods to assess perinatal fetal heart function in normal term pregnancies. The aim of this study was to characterize cardiac geometry and function in normal term fetuses and neonates and to describe how perinatal changes in loading conditions may have an impact on such parameters.


Methods


This was a prospective longitudinal study involving the fetuses of women with apparently uncomplicated pregnancies and their newborn babies. Pregnant women attending for routine antenatal care at St. George’s Hospital between November 2012 and May 2014 were recruited if the pregnancies were assessed as normal and fetuses had structurally normal hearts. Exclusion criteria were fetal structural abnormality, impaired fetal growth, any maternal prepregnancy or pregnancy-related comorbidity, and pregnant women in labor. All participants gave written consent for fetal and neonatal echocardiogram. The Ethics Committee of NRES Committee London-Surrey Borders approved the study protocol (reference no. 12/LO/0945).


Fetal M-mode, two-dimensional (2D) or B-mode, spectral or pulsed wave (PW) Doppler, PW TDI, and STI echocardiograms were performed few days before birth. Neonatal cardiac assessment was conducted within hours after birth. One investigator (O.P.) performed all ultrasound examinations using a Toshiba Aplio MX ultrasound system (Toshiba Medical Systems, Japan). Fetal M-mode, B-mode, and PW Doppler measurements were made with the convex array transducer PVT-375BT (3.5 MHz), while the sector pediatric heart probe PST-65AT (6.5 MHz) was used for neonatal heart examination. Fetal and neonatal PW-TDI curves and 2D images for STI analysis were obtained and recorded with the multisector tissue harmonic transducer PST-30 BT (3 MHz) with TDI mode activated. All neonatal examinations were recorded with simultaneous electrocardiogram (ECG). In the absence of a fetal ECG, the cardiac cycle was determined from a dummy ECG device (Lionheart 2 BIO-TEK Multiparameter Simulator, BIO-TEK Instruments, Inc., Winooski, VT) and mechanical movements of the atrioventricular valves (AVVs).


M-mode ultrasound was used for assessment of LV shortening fraction (SF) and longitudinal axis ventricular systolic function. B-mode (2D) imaging was performed to measure ventricular chambers (right ventricular [RV] and LV end-diastolic dimensions [EDDs], end-systolic dimensions [ESDs], RV/LV EDD ratio, ventricular end-diastolic and end-systolic areas, and RV and LV sphericity index calculated by dividing ventricular EDD by ventricular end-diastolic length in the apical/basal four-chamber view), ventricular wall thickness, and valve diameters. The PW Doppler technique was used to obtain Doppler signals from the inflow and outflow tracts for evaluation of diastolic and systolic function, respectively, for calculation of stroke volume (SV) and cardiac output (CO) and for estimation of LV myocardial performance index (MPI). The PW-TDI technique was applied to derive cardiac indices of myocardial motion S′ as well as E′ and A′ and was also used for estimation of MPI for both right and left ventricles (MPI′). All echocardiographic measurements were performed according to the standardized protocol of the study and with regards to previously described fetal echo techniques (see the Supplemental Data , available at www.onlinejase.com ). For fetal STI, care was taken to obtain 2D four-chamber apical or basal images. The narrowest possible ultrasound field and a single focal zone were used during image acquisition to obtain the frame rates greater than 100 frames per second (fps). These settings provided an acceptable combination of high temporal resolution with spatial definition to enhance the feasibility of the frame-by-frame tracking technique. Following the observation of several fetal heart beats, the real-time image was frozen, and one cardiac cycle was recorded. With the dummy ECG set at 60 bpm, the system was able to capture at least one whole fetal cardiac cycle with real fetal heart rate of 120–150 bpm. When several digital clips were obtained, raw data were transferred to a computer for offline analysis with frame rates greater than 100 fps using a dedicated software (TDI and STI Toshiba software Advanced Cardiac Package, Toshiba Medical Systems, Japan) on a BTO laptop. The 2D clips were visually inspected, and the one with the best endocardial border definition was chosen for STI analysis. The cardiac cycle was defined with M-mode function (M-Graph) incorporated into the Toshiba software whereby an M-mode trace was obtained by placing a cursor line on the 2D image. This provided a guide to set the R wave position. Visualization of opening (start of the diastole) and closure (start of systole) of AVVs was used to confirm definition of the cardiac cycle. The endocardial and epicardial surfaces of the myocardial segment were manually traced by a point-and-click approach. When the trace was recognized and accepted by the software, it was then automatically generated by the system by creating a region of interest and providing segmental longitudinal strain and strain rate values and then generated strain and strain rate curves for each selected myocardial segment. From these curves, the regional and global (by averaging values observed in all six segments) peak values were obtained. The peak systolic values of global and segmental longitudinal strain and systolic longitudinal strain rate were recorded for LV and RV separately. All temporal indices (PW-TDI derived time intervals) were adjusted for heart rate by dividing the values by the cardiac cycle length (all crude values are presented in the Supplemental Data , available at www.onlinejase.com ).


Sample size and power calculations were performed prior to the study based on our pilot data and the previous research study. For the systolic strain rate as a primary outcome, a sample of 80 fetuses and 80 neonates would detect a rate of deformational change (1/sec) difference of 0.74 (equivalent to 10% of the mean, 3.69), with a power of 85%, a significance level of 5%, and assuming a standard deviation of 1.10. To allow for possible confounding factors including dropouts, this number was increased to 100 fetuses and 100 neonates. Statistical analysis was performed using SPSS version 22.0 (SPSS Inc., Chicago, IL). Both Shapiro-Wilk and Kolmogorov-Smirnov tests were performed to test normality. If P > .05, the data distribution was considered to be normal. For normally distributed data, a paired t -test was used to test the null hypothesis that there was no difference in the means between the fetal and neonatal values. Skewed data were analyzed with nonparametric test (Wilcoxon signed rank test). The level of significance was adjusted for multiple measurements. The differences between prenatal and postnatal measurements were deemed as significant only if P < .001 (Bonferroni correction for type 1 error or false-positive results of multiple measurements).


B-mode, M-mode, PW Doppler, TDI, and STI measurements of 25 fetal and 25 neonatal echoes were repeated by the same observer (O.P.) on a Toshiba Aplio MX ultrasound machine in the same frame for calculation of the measurement error and in a different frame for calculation of the overall error (combined acquisition and measurement errors). In randomly chosen 10 fetal and 10 neonatal echocardiograms, two different observers (V.D.Z. and B.S.) repeated TDI measurements on Toshiba Aplio MX and STI indices on vendor-specific Advanced Cardiac Package software in the same frame and then in a different frame. The observers were blinded to each other’s measurements. Both limits of agreement (LoA) with Bland-Altman graphs/Pitman’s test of difference in variance and intraclass correlation coefficient (ICC) were calculated.




Results


A total of 118 women consented to the study. Of these, paired fetal and neonatal data were available for 108 cases. All 108 neonates had a small (≤2 mm) patent foramen ovale, whereas a small patent ductus arteriosus (≤2–3 mm) was present in 102 (94%) neonates. After birth, the presence of structurally normal heart was confirmed in all 108 neonates. Demographic characteristics and echocardiographic scan details are summarized in Table 1 .



Table 1

Demographic characteristic of the study population










































Parameter Characteristics
Maternal characteristics ( N = 108)
Maternal age (years) 34 ± 5
Ethnicity (no.)
Caucasian 80 (74%)
Asian 21 (19%)
Afro-Caribbean 7 (7%)
Fetal cardiac assessment ( N = 108)
Gestational age (weeks) 39 ± 1.5
Time gap between fetal scan and birth (days) 8 (10)
Neonatal cardiac assessment ( N = 108)
Neonate’s age at the time of scan (hours) 13 (16)
Neonate’s sex male (number) 58 (54%)
Neonate’s weight (kg) 3.51 ± 0.47

Values are mean ± SD, median (interquartile range), or n (%).


Morphometric Measurements by B-Mode and M-Mode


Morphometric measurements by 2D imaging (B-mode) demonstrated a significant decrease in RV EDD, RV/LV EDD ratio, RV AVV dimension, RV/LV AVV dimension ratio, RV/LV end-diastolic area ratio, RV sphericity index and thickness of LV, RV walls, and interventricular septum (IVS; Table 2 and Table S1 , available at www.onlinejase.com , Figure 1 ). There was also a significant increase in aortic and pulmonary valve dimension, LV EDD, LV ESD, LV AVV dimension, LV end-diastolic area, both LV and RV end-diastolic length, and LV sphericity index ( Tables 2 and Table S1 , available at www.onlinejase.com ).



Table 2

Perinatal changes in cardiac geometry












































Measurements Fetal Neonatal P value
RV sphericity index 0.53 ± 0.09 0.40 ± 0.05 <.0001
LV sphericity index 0.46 ± 0.09 0.49 ± 0.05 .001
RV/LV end-diastolic area ratio 1.10 (0.37) 0.80 (0.20) <.0001
RV/LV AVV dimension ratio 1.16 (0.20) 1.02 (0.18) <.0001
RV wall thickness, mm 3.8 (0.8) 3.2 (0.9) <.0001
LV wall thickness, mm 3.7 (0.8) 3.2 (0.5) <.0001
IVS thickness, mm 3.6 ± 0.6 3.2 ± 0.6 <.0001

Data are mean ± SD, median (interquartile range).

The sphericity index is the cardiac index calculated by dividing ventricular EDD by ventricular end-diastolic length measured in the apical/basal four-chamber view.




Figure 1


Perinatal changes in cardiac chamber geometry. Linear plots of all 108 patients showing a significant ( P < .0001) decrease in (A) RV/LV EDD ratio and (B) RV sphericity index from fetus to neonate.


Hemodynamic Indices


The LV SF did not differ perinatally. There was evidence of a significant postnatal increase in LV SV and LV CO, while RV SV and RV CO decreased significantly after birth with a significant drop in neonatal heart rate ( Table 3 and Table S2 , available at www.onlinejase.com ).



Table 3

Perinatal changes in indices of cardiac function































































































































Measurements Fetal Neonatal P value
Hemodynamics
Heart rate (bpm) 140 (13) 117 (16) <.0001
LV CO (mL/min/kg) 212 ± 55 275 ± 65 <.0001
RV CO (mL/min/kg) 279 ± 77 211 ± 54 <.0001
Global myocardial performance
LV MPI′ 0.60 (0.21) 0.47 (0.10) <.0001
RV MPI′ 0.61 ± 0.14 0.42 ± 0.08 <.0001
Systolic function
LV longitudinal axis motion (mm) 7.1 (1.7) 6.6 (1.5) .020
IVS longitudinal axis motion (mm) 5.8 (1.7) 5.4 (1.4) .074
RV longitudinal axis motion (mm) 8.7 (2.8) 9.0 (2.2) .125
LV global longitudinal systolic strain rate (1/sec) −1.4 (0.9) −1.0 (0.4) <.0001
RV global longitudinal systolic strain rate (1/sec) −1.5 (0.7) −1.0 (0.6) <.0001
LV S′ (cm/sec) 5.2 ± 1.4 5.1 ± 0.8 .473
LV ET′ (sec) 0.37 ± 0.05 0.39 ± 0.05 .017
LV IVCT′ (sec) 0.12 ± 0.02 0.09 ± 0.02 <.0001
RV ET′ (sec) 0.39 ± 0.05 0.41 ± 0.05 <.0001
RV IVCT′ (sec) 0.11 (0.054) 0.08 (0.03) <.0001
Diastolic function
LV E/A ratio 0.8 (0.2) 1.2 (0.3) <.0001
RV E/A ratio 0.7 (0.2) 0.9 (0.4) <.0001
LV E′/A′ ratio 0.8 (0.5) 1.1 (0.5) <.0001
IVS E′/A′ ratio 0.7 (0.3) 0.8 (0.4) <.0001
RV E/E′ ratio 7.7 (3.8) 6.4 (3.0) .023
LV IVRT′ (sec) 0.11 (0.03) 0.09 (0.02) <.0001
RV IVRT′ (sec) 0.11 (0.04) 0.09 (0.02) <.0001

MPI′ , MPI obtained by PW-TDI.

Data are mean ± SD, or median (interquartile range).

Values adjusted by cardiac cycle length.



Longitudinal Axis Annular Motion Changes and MPI Changes


There were no significant changes in the RV, LV, and IVS longitudinal axis systolic annular motion ( Table 3 ). There was a significant decrease in RV MPI′ and LV MPI and MPI′ ( Table 3 and Table S2 , available at www.onlinejase.com , and Figure 2 ).




Figure 2


Perinatal changes in MPI. Box-and-whisker plots demonstrating a significant ( P < .0001) perinatal decrease in LV and RV MPI′ obtained by PW-TDI in fetus and neonate.


Myocardial Deformation Changes by STI


The mean frame rate ± SD obtained for STI analysis was 135 ± 14 fps for fetuses and 128 ± 11 fps for neonates. The global longitudinal strain rate showed a significant decrease of systolic peak in both ventricles, and regional myocardial deformation analysis demonstrated a significant perinatal decrease in longitudinal systolic strain rate in most segments ( Table 3 and Table S3 , available at www.onlinejase.com ).


PW Doppler and PW-TDI Indices


There was a significant increase in systolic annular peak velocities (S′) for the right ventricle and the IVS but not for the left ventricle ( Table 3 and Figure 3 ). There was a significant increase in RV ejection time (ET) and a significant decrease in both RV and LV isovolumetric contraction time (IVCT; Table 3 ). Diastolic function indices showed a significant increase in both LV and RV E/A ratio. Similarly, spectral TDI demonstrated a significant increase in diastolic LV E′/A′ ratio and IVS E′/A′ ratio and a significant decrease in both LV and RV isovolumetric relaxation time (IVRT; Table 3 and Figure 3 ).




Figure 3


Perinatal changes in cardiac systolic and diastolic function. PW-TDI-derived RV systolic (S′) and diastolic (E′ and A′) myocardial velocity measurements in (A) fetus and (B) neonate. Box-and-whisker plots showing a significant ( P < .0001) perinatal increase in (C) RV and IVS systolic myocardial velocities S′ and (D) LV and IVS diastolic myocardial velocity ratio E′/A′ from fetus to neonate.


Reproducibility and Repeatability


The LoA and ICC showed good to excellent intra- and interobserver agreement of all fetal and neonatal conventional TDI and STI indices in the same frame (ICC = 0.8–0.9). When all measurements were repeated in a different frame, the correlation and agreement remained excellent to good for both fetal and neonatal conventional and TDI parameters and showed moderate to good correlation (ICC = 0.6–0.7) and good to excellent agreement for fetal and neonatal STI indices ( Table S4 , available at www.onlinejase.com ).




Results


A total of 118 women consented to the study. Of these, paired fetal and neonatal data were available for 108 cases. All 108 neonates had a small (≤2 mm) patent foramen ovale, whereas a small patent ductus arteriosus (≤2–3 mm) was present in 102 (94%) neonates. After birth, the presence of structurally normal heart was confirmed in all 108 neonates. Demographic characteristics and echocardiographic scan details are summarized in Table 1 .



Table 1

Demographic characteristic of the study population










































Parameter Characteristics
Maternal characteristics ( N = 108)
Maternal age (years) 34 ± 5
Ethnicity (no.)
Caucasian 80 (74%)
Asian 21 (19%)
Afro-Caribbean 7 (7%)
Fetal cardiac assessment ( N = 108)
Gestational age (weeks) 39 ± 1.5
Time gap between fetal scan and birth (days) 8 (10)
Neonatal cardiac assessment ( N = 108)
Neonate’s age at the time of scan (hours) 13 (16)
Neonate’s sex male (number) 58 (54%)
Neonate’s weight (kg) 3.51 ± 0.47

Values are mean ± SD, median (interquartile range), or n (%).


Morphometric Measurements by B-Mode and M-Mode


Morphometric measurements by 2D imaging (B-mode) demonstrated a significant decrease in RV EDD, RV/LV EDD ratio, RV AVV dimension, RV/LV AVV dimension ratio, RV/LV end-diastolic area ratio, RV sphericity index and thickness of LV, RV walls, and interventricular septum (IVS; Table 2 and Table S1 , available at www.onlinejase.com , Figure 1 ). There was also a significant increase in aortic and pulmonary valve dimension, LV EDD, LV ESD, LV AVV dimension, LV end-diastolic area, both LV and RV end-diastolic length, and LV sphericity index ( Tables 2 and Table S1 , available at www.onlinejase.com ).



Table 2

Perinatal changes in cardiac geometry












































Measurements Fetal Neonatal P value
RV sphericity index 0.53 ± 0.09 0.40 ± 0.05 <.0001
LV sphericity index 0.46 ± 0.09 0.49 ± 0.05 .001
RV/LV end-diastolic area ratio 1.10 (0.37) 0.80 (0.20) <.0001
RV/LV AVV dimension ratio 1.16 (0.20) 1.02 (0.18) <.0001
RV wall thickness, mm 3.8 (0.8) 3.2 (0.9) <.0001
LV wall thickness, mm 3.7 (0.8) 3.2 (0.5) <.0001
IVS thickness, mm 3.6 ± 0.6 3.2 ± 0.6 <.0001

Data are mean ± SD, median (interquartile range).

The sphericity index is the cardiac index calculated by dividing ventricular EDD by ventricular end-diastolic length measured in the apical/basal four-chamber view.




Figure 1


Perinatal changes in cardiac chamber geometry. Linear plots of all 108 patients showing a significant ( P < .0001) decrease in (A) RV/LV EDD ratio and (B) RV sphericity index from fetus to neonate.


Hemodynamic Indices


The LV SF did not differ perinatally. There was evidence of a significant postnatal increase in LV SV and LV CO, while RV SV and RV CO decreased significantly after birth with a significant drop in neonatal heart rate ( Table 3 and Table S2 , available at www.onlinejase.com ).



Table 3

Perinatal changes in indices of cardiac function































































































































Measurements Fetal Neonatal P value
Hemodynamics
Heart rate (bpm) 140 (13) 117 (16) <.0001
LV CO (mL/min/kg) 212 ± 55 275 ± 65 <.0001
RV CO (mL/min/kg) 279 ± 77 211 ± 54 <.0001
Global myocardial performance
LV MPI′ 0.60 (0.21) 0.47 (0.10) <.0001
RV MPI′ 0.61 ± 0.14 0.42 ± 0.08 <.0001
Systolic function
LV longitudinal axis motion (mm) 7.1 (1.7) 6.6 (1.5) .020
IVS longitudinal axis motion (mm) 5.8 (1.7) 5.4 (1.4) .074
RV longitudinal axis motion (mm) 8.7 (2.8) 9.0 (2.2) .125
LV global longitudinal systolic strain rate (1/sec) −1.4 (0.9) −1.0 (0.4) <.0001
RV global longitudinal systolic strain rate (1/sec) −1.5 (0.7) −1.0 (0.6) <.0001
LV S′ (cm/sec) 5.2 ± 1.4 5.1 ± 0.8 .473
LV ET′ (sec) 0.37 ± 0.05 0.39 ± 0.05 .017
LV IVCT′ (sec) 0.12 ± 0.02 0.09 ± 0.02 <.0001
RV ET′ (sec) 0.39 ± 0.05 0.41 ± 0.05 <.0001
RV IVCT′ (sec) 0.11 (0.054) 0.08 (0.03) <.0001
Diastolic function
LV E/A ratio 0.8 (0.2) 1.2 (0.3) <.0001
RV E/A ratio 0.7 (0.2) 0.9 (0.4) <.0001
LV E′/A′ ratio 0.8 (0.5) 1.1 (0.5) <.0001
IVS E′/A′ ratio 0.7 (0.3) 0.8 (0.4) <.0001
RV E/E′ ratio 7.7 (3.8) 6.4 (3.0) .023
LV IVRT′ (sec) 0.11 (0.03) 0.09 (0.02) <.0001
RV IVRT′ (sec) 0.11 (0.04) 0.09 (0.02) <.0001

MPI′ , MPI obtained by PW-TDI.

Data are mean ± SD, or median (interquartile range).

Values adjusted by cardiac cycle length.



Longitudinal Axis Annular Motion Changes and MPI Changes


There were no significant changes in the RV, LV, and IVS longitudinal axis systolic annular motion ( Table 3 ). There was a significant decrease in RV MPI′ and LV MPI and MPI′ ( Table 3 and Table S2 , available at www.onlinejase.com , and Figure 2 ).




Figure 2


Perinatal changes in MPI. Box-and-whisker plots demonstrating a significant ( P < .0001) perinatal decrease in LV and RV MPI′ obtained by PW-TDI in fetus and neonate.


Myocardial Deformation Changes by STI


The mean frame rate ± SD obtained for STI analysis was 135 ± 14 fps for fetuses and 128 ± 11 fps for neonates. The global longitudinal strain rate showed a significant decrease of systolic peak in both ventricles, and regional myocardial deformation analysis demonstrated a significant perinatal decrease in longitudinal systolic strain rate in most segments ( Table 3 and Table S3 , available at www.onlinejase.com ).


PW Doppler and PW-TDI Indices


There was a significant increase in systolic annular peak velocities (S′) for the right ventricle and the IVS but not for the left ventricle ( Table 3 and Figure 3 ). There was a significant increase in RV ejection time (ET) and a significant decrease in both RV and LV isovolumetric contraction time (IVCT; Table 3 ). Diastolic function indices showed a significant increase in both LV and RV E/A ratio. Similarly, spectral TDI demonstrated a significant increase in diastolic LV E′/A′ ratio and IVS E′/A′ ratio and a significant decrease in both LV and RV isovolumetric relaxation time (IVRT; Table 3 and Figure 3 ).


Apr 15, 2018 | Posted by in CARDIOLOGY | Comments Off on Perinatal Changes in Fetal Ventricular Geometry, Myocardial Performance, and Cardiac Function in Normal Term Pregnancies

Full access? Get Clinical Tree

Get Clinical Tree app for offline access