Magnetic resonance angiography

Chapter 8 Magnetic resonance angiography





MRA techniques





Post-processing methods


Post-processing algorithms are used to create 3D images. However, they must always be interpreted together with the source images, the ‘raw data’, to avoid misinterpretation from post-processing induced artefacts (Figure 8.2).






Curved multiplanar reconstruction


Curved multiplanar reconstruction (MPR) can be used to obtain images in views other than that of the native acquisition (Figure 9.3). These work particularly well on 3D data sets with isotropic voxels in which resolution is identical in any obtained plane.



Specific Sites



Carotid arteries


The most commonly used sequences for carotid MRA are time-of-flight and CE-MRA (Figure 8.1). For imaging of the aortic arch and cervical arteries, CE-MRA is the only option. Both 3D TOF and CE-MRA are as accurate as conventional X-ray angiography in the measurement of internal carotid artery stenosis, and because of the small but significant risk of stroke with the invasive technique (0.5–1.0%), CMR is recommended as the optimal method of evaluating carotid artery disease. Data interpretation requires careful evaluation of the raw data to avoid overestimation of stenosis severity. MIP projections will aggravate signal loss and cause vessels to appear narrower because the algorithm selects brightest intensities both within the vessel and in the background. Such overestimation with MIPs is more of a problem in 3D time-of-flight than with CE-MRA, in which background intensities are suppressed.


MRA is excellent for the diagnosis of carotid dissection. Dissection typically consists of haemorrhage in the media, sometimes extending into the adventitia, and the intimal flap is not always apparent. Angiography identifies a smooth or irregular narrowing and high-resolution SE images with fat saturation prepulse can help to identify the false lumen.

Stay updated, free articles. Join our Telegram channel

Jun 11, 2016 | Posted by in CARDIOLOGY | Comments Off on Magnetic resonance angiography

Full access? Get Clinical Tree

Get Clinical Tree app for offline access