Chapter 2
Questions
- 21. Doppler shift is typically in:
- A. Ultrasound range
- B. Infrasound range
- C. Audible range
- A. Ultrasound range
- 22. Duty factor refers to:
- A. Power the transducer can generate
- B. Range of frequencies the transducer is capable of
- C. Physical properties of the damping material
- D. Fraction of time the transducer is emitting ultrasound
- A. Power the transducer can generate
- 23. Duty factor increases with:
- A. Increasing gain
- B. Increasing pulse duration
- C. Decreasing pulse repetition frequency (PRF)
- D. Decreasing dynamic range
- A. Increasing gain
- 24. Which of the following will increase the PRF?
- A. Reducing depth
- B. Decreasing transducer frequency
- C. Reducing sector angle
- D. Reducing filter
- A. Reducing depth
- 25. Persistence will have this effect on the image:
- A. Smoothening of a two-dimensional image
- B. Better resolution
- C. Eliminating artifacts
- D. Spuriously reducing wall thickness
- A. Smoothening of a two-dimensional image
- 26. Aliasing occurs in this type of imaging:
- A. Pulsed wave Doppler
- B. Continuous wave Doppler
- C. None of the above
- D. All of the above
- A. Pulsed wave Doppler
- 27. The Nyquist limit at a PRF of 1000 Hz is:
- A. 500 Hz
- B. 1000 Hz
- C. 2000 Hz
- D. Cannot calculate
- 28. The Nyquist limit can be increased by:
- A. Increasing the PRF
- B. Reducing the PRF
- C. Neither
- 29. The Nyquist limit can also be increased by:
- A. Increasing transducer frequency
- B. Reducing transducer frequency
- C. Reducing filter
- D. None of the above
- 30. Aliasing can be reduced by:
- A. Decreasing the depth
- B. Increasing the PRF
- C. Reducing the transducer frequency
- D. Changing to continuous wave Doppler
- E. All of the above
- 31. What is the purpose of the depth or time gain compensation process adjusted by the echo cardiographer and performed in an ultrasound’s receiver?
- A. Corrects for depth attenuation and makes the image uniformly bright
- B. Eliminates image artifacts
- C. Eliminates aliasing
- D. None of the above
- 32. Which of the following increases the Nyquist limit?
- A. Increasing the depth
- B. Reducing the sample volume depth
- C. Increasing the transducer frequency
- D. None of the above
- 33. The maximum Doppler shift that can be displayed without aliasing with a PRF of 10 kHz is:
- A. 5 kHz
- B. 10 kHz
- C. Depends on depth
- D. Cannot be determined
- 34. The PRF is influenced by:
- A. Transducer frequency
- B. Depth of imaging
- C. Both
- D. Neither
- 35. Two identical structures appear on an ultrasound scan. One is real and the other is an artifact, the artifact being deeper than the real structure. What is this artifact called?
- A. Shadowing
- B. Ghosting
- C. Speed error artifact
- D. Mirror image